Administrator
|
While working on an assignment for a 4th year class (using v25), I noticed
that the PLOT dialog for UNIANOVA now allows the user to choose either a line graph (the only option available previously) or a bar graph. About time, I thought, as many of us teach students that line graphs are only appropriate when the X-axis variable is quantitative in nature. It turns out this is not the only nice improvement to UNIANOVA. See below for the complete list of changes. Changes to UNIANOVA in Release 25.0 TYPE, ERRORBAR, MEANREFERENCE, and YAXIS keywords added to PLOT subcommand. ROBUST subcommand added. HCCOVB keyword added to OUTFILE subcommand. Any combination of COVB, CORB, and HCCOVB keywords can now be specified on OUTFILE. MBP, BP, F, and WHITE keywords added to PRINT subcommand. MBPDESIGN, BPDESIGN, and FDESIGN subcommands added. For more info: https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova.html https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_plot.html https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_robust.html https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_outfile.html https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_print.html https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_hc_designs.html ----- -- Bruce Weaver [hidden email] http://sites.google.com/a/lakeheadu.ca/bweaver/ "When all else fails, RTFM." NOTE: My Hotmail account is not monitored regularly. To send me an e-mail, please use the address shown above. -- Sent from: http://spssx-discussion.1045642.n5.nabble.com/ ===================== To manage your subscription to SPSSX-L, send a message to [hidden email] (not to SPSSX-L), with no body text except the command. To leave the list, send the command SIGNOFF SPSSX-L For a list of commands to manage subscriptions, send the command INFO REFCARD
--
Bruce Weaver bweaver@lakeheadu.ca http://sites.google.com/a/lakeheadu.ca/bweaver/ "When all else fails, RTFM." PLEASE NOTE THE FOLLOWING: 1. My Hotmail account is not monitored regularly. To send me an e-mail, please use the address shown above. 2. The SPSSX Discussion forum on Nabble is no longer linked to the SPSSX-L listserv administered by UGA (https://listserv.uga.edu/). |
Administrator
|
As Jon Peck pointed out to me in a private message, all of these features
have also been added to GLM. https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/advanced/syn_glm_overview.html Bruce Weaver wrote > While working on an assignment for a 4th year class (using v25), I noticed > that the PLOT dialog for UNIANOVA now allows the user to choose either a > line graph (the only option available previously) or a bar graph. About > time, I thought, as many of us teach students that line graphs are only > appropriate when the X-axis variable is quantitative in nature. It turns > out this is not the only nice improvement to UNIANOVA. See below for the > complete list of changes. > > > Changes to UNIANOVA in Release 25.0 > > TYPE, ERRORBAR, MEANREFERENCE, and YAXIS keywords added to PLOT > subcommand. > ROBUST subcommand added. > HCCOVB keyword added to OUTFILE subcommand. Any combination of COVB, > CORB, and HCCOVB keywords can now be specified on OUTFILE. > MBP, BP, F, and WHITE keywords added to PRINT subcommand. > MBPDESIGN, BPDESIGN, and FDESIGN subcommands added. > > For more info: > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_plot.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_robust.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_outfile.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_print.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_hc_designs.html > > > > > > > ----- > -- > Bruce Weaver > bweaver@ > http://sites.google.com/a/lakeheadu.ca/bweaver/ > > "When all else fails, RTFM." > > NOTE: My Hotmail account is not monitored regularly. > To send me an e-mail, please use the address shown above. > > -- > Sent from: http://spssx-discussion.1045642.n5.nabble.com/ > > ===================== > To manage your subscription to SPSSX-L, send a message to > LISTSERV@.UGA > (not to SPSSX-L), with no body text except the > command. To leave the list, send the command > SIGNOFF SPSSX-L > For a list of commands to manage subscriptions, send the command > INFO REFCARD ----- -- Bruce Weaver [hidden email] http://sites.google.com/a/lakeheadu.ca/bweaver/ "When all else fails, RTFM." NOTE: My Hotmail account is not monitored regularly. To send me an e-mail, please use the address shown above. -- Sent from: http://spssx-discussion.1045642.n5.nabble.com/ ===================== To manage your subscription to SPSSX-L, send a message to [hidden email] (not to SPSSX-L), with no body text except the command. To leave the list, send the command SIGNOFF SPSSX-L For a list of commands to manage subscriptions, send the command INFO REFCARD
--
Bruce Weaver bweaver@lakeheadu.ca http://sites.google.com/a/lakeheadu.ca/bweaver/ "When all else fails, RTFM." PLEASE NOTE THE FOLLOWING: 1. My Hotmail account is not monitored regularly. To send me an e-mail, please use the address shown above. 2. The SPSSX Discussion forum on Nabble is no longer linked to the SPSSX-L listserv administered by UGA (https://listserv.uga.edu/). |
Administrator
|
In reply to this post by Bruce Weaver
As pleased as I was to see the ROBUST sub-command added to UNIANOVA (and GLM)
in v25, I was quite quite surprised and ~disappointed~ to discover that contrasts carried out via EMMEANS with COMPARE do not use the robust standard errors. (I discovered this while cobbling together a toy example for a student.) In order to obtain contrasts that use the robust SEs, one must use LMATRIX. (And if you've ever used LMATRIX, I suspect you'll agree it's considerably trickier than EMMEANS with COMPARE.) What I expected to find was that if I use a ROBUST sub-command, all tests and contrasts would use the robust SEs. But instead, UNIANOVA (and GLM) give the usual output (with asymptotic SEs--ASEs) and then tack on some more output using robust SEs. From the FM: --- start of excerpt --- ROBUST displays a table of parameter estimates, along with robust or heteroskedasticity-consistent (HC) standard errors; and t statistics, significance values, and confidence intervals that use the robust standard errors. - ROBUST enables specification of the HCCOVB keyword on the OUTFILE subcommand, saving the robust covariance matrix estimates to a new file or dataset. - ROBUST displays a second set of output for any custom hypothesis tests that are specified on LMATRIX subcommands, with results based on the specified robust covariance matrix estimator. --- end of excerpt --- Source: https://www.ibm.com/support/knowledgecenter/en/SSLVMB_26.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_robust.html IMO, when a user includes a ROBUST sub-command, it would be FAR more convenient (and less confusing) to simply show the usual output using robust SEs in place of the ASEs. This is what happens in Stata, for example, when one uses the vce() option on -regress-. Bruce Bruce Weaver wrote > While working on an assignment for a 4th year class (using v25), I noticed > that the PLOT dialog for UNIANOVA now allows the user to choose either a > line graph (the only option available previously) or a bar graph. About > time, I thought, as many of us teach students that line graphs are only > appropriate when the X-axis variable is quantitative in nature. It turns > out this is not the only nice improvement to UNIANOVA. See below for the > complete list of changes. > > > Changes to UNIANOVA in Release 25.0 > > TYPE, ERRORBAR, MEANREFERENCE, and YAXIS keywords added to PLOT > subcommand. > ROBUST subcommand added. > HCCOVB keyword added to OUTFILE subcommand. Any combination of COVB, > CORB, and HCCOVB keywords can now be specified on OUTFILE. > MBP, BP, F, and WHITE keywords added to PRINT subcommand. > MBPDESIGN, BPDESIGN, and FDESIGN subcommands added. > > For more info: > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_plot.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_robust.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_outfile.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_print.html > > https://www.ibm.com/support/knowledgecenter/en/SSLVMB_25.0.0/statistics_reference_project_ddita/spss/base/syn_unianova_hc_designs.html > > > > > > > ----- > -- > Bruce Weaver > bweaver@ > http://sites.google.com/a/lakeheadu.ca/bweaver/ > > "When all else fails, RTFM." > > NOTE: My Hotmail account is not monitored regularly. > To send me an e-mail, please use the address shown above. > > -- > Sent from: http://spssx-discussion.1045642.n5.nabble.com/ > > ===================== > To manage your subscription to SPSSX-L, send a message to > LISTSERV@.UGA > (not to SPSSX-L), with no body text except the > command. To leave the list, send the command > SIGNOFF SPSSX-L > For a list of commands to manage subscriptions, send the command > INFO REFCARD ----- -- Bruce Weaver [hidden email] http://sites.google.com/a/lakeheadu.ca/bweaver/ "When all else fails, RTFM." NOTE: My Hotmail account is not monitored regularly. To send me an e-mail, please use the address shown above. -- Sent from: http://spssx-discussion.1045642.n5.nabble.com/ ===================== To manage your subscription to SPSSX-L, send a message to [hidden email] (not to SPSSX-L), with no body text except the command. To leave the list, send the command SIGNOFF SPSSX-L For a list of commands to manage subscriptions, send the command INFO REFCARD
--
Bruce Weaver bweaver@lakeheadu.ca http://sites.google.com/a/lakeheadu.ca/bweaver/ "When all else fails, RTFM." PLEASE NOTE THE FOLLOWING: 1. My Hotmail account is not monitored regularly. To send me an e-mail, please use the address shown above. 2. The SPSSX Discussion forum on Nabble is no longer linked to the SPSSX-L listserv administered by UGA (https://listserv.uga.edu/). |